﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	severity	resolution	keywords	cc
425	SMART-Fehler auf LTSP-Platten	Rüdiger Kupper	Rüdiger Kupper	"Aus den Syslogs der Server:

 ltsp118:: Dec 19 16:16:51 ltsp118 smartd[1500]: Device: /dev/sda [SAT], 6 Currently unreadable (pending) sectors

 ltsp126:: Dec 19 08:15:56 ltsp126 smartd[1609]: Device: /dev/sda [SAT], SMART Usage Attribute: 190 Airflow_Temperature_Cel changed from 67 to 68

 ltsp138:: -nichts-

 ltsp146::  Dec 19 12:47:08 ltsp145 smartd[1423]: Device: /dev/sda [SAT], SMART Usage Attribute: 190 Airflow_Temperature_Cel changed from 67 to 68

 LTServer128a:: - nichts -
 
 LTServer128b:: Dec 19 08:16:02 LTServer128b smartd[1427]: Device: /dev/sda [SAT], SMART Usage Attribute: 194 Temperature_Celsius changed from 64 to 63

 LTServer128c:: Dec 19 08:33:44 LTServer128c smartd[1539]: Device: /dev/sda [SAT], SMART Usage Attribute: 194 Temperature_Celsius changed from 64 to 63


-> Die Platte im ltsp118 muss ersetzt werden!
-> Die Platten werden zu heiß! (Betriebstemperatur sollte unterhalb 55 Grad C liegen!)"	Defekt	closed	schnell erledigen	Schuljahr 2011/12	Server: Linux Terminal Server (LTSP)	beeinträchtigt den Unterricht einiger Lehrer	erledigt		bau